mag-flux F5

Magnetic-inductive sensor suitable for measuring small and very small quantities

This special type of magnetic-inductive sensors (MID) is particularly suitable for measuring flows of very small quantities and especially for use in portioning and metering tasks. Combined with the Transmag 2 measuring transducer, the integrated metering software can solve complex metering challenges.

The magnetic-inductive sensor is recommended for flow measurement of electrically conductive liquids – especially for measuring very small quantities. The mag-flux F5 is available in nominal sizes DN 2 to DN 12.

The image shows a magnetic-inductive sensor (MID) mag-flux F5 is suitable for measuring flows of very small quantities

Area of application:

Typical applications of the mag-flux F5 flow meter are measuring very small quantities and metering chemicals and pharmaceuticals.

The magnetic-inductive sensor is used in the following industries:

  • Plant and mechanical engineering
  • Chemicals
  • Laboratory and medical technology
  • Food
  • Water and wastewater

Advantages of the magnetic-inductive flow meter for measuring very small quantities:

  • Reliability (long-term stability, service life)
  • Minimal maintenance requirements
  • Simple commissioning
  • High measurement accuracy
  • Flexible installation position (however the measuring tube must be completely full at all times)
  • Manufacturer’s application expertise
  • Short lead times

Special features of the flow meter:

  • Measuring tube made of highly corrosion and temperature-resistant zirconium oxide
  • Measuring tube internal diameter from 2 mm (0.078")
  • Robust and interference-free thanks to sealed steel casing

Very low measuring ranges:

  • 0 to 5 l/h (0 to 0.022 USgpm) for d.c. measurement
  • 0 to 3 l/h (0 to 0.0132 USgpm) for a.c. measurement

Very low minimum conductivity:

  • 10 μS/cm for d.c. measurement
  • 0.1 μS/cm for a.c. measurement

Various process connections:

  • Threads: DIN, NPT, BSP
  • Flange: DIN, ANSI, JIS
  • Clamp
  • DIN 11851
  • Others on request

Various process connection materials:

  • M. No. 1.4571
  • Hastelloy C4 M. No. 2.4610
  • PVDF with in Hastelloy C4 M. No. 2.4610 earthing ring
  • Titanium
  • Others on request
Operating principle pulsed constant field (DC)
Measuring accuracy¹ error of measurement: ±0,4 % ±1 mm/s of MV
repeatability: ± 0,15 % of MV
Liquids min. conductivity: 20 μS/cm
min. flow velocity: 0.25 m/s (0.82 ft/s)
max. flow velocity: 10 m/s (32.8 ft/s)
Temperature limits process connection - metal:
0 °C to +150 °C
process connection - PVDF:
+120 °C / 3 bar; +50 °C  / 10 bar

Tube materials zirconium oxide
Electrodes materials platinium 99,9 %, sintered
Process connections Thread: DIN, NPT, BSP
Flange: ANSI B 16.5
(Tri-) Camp/DIN 11851
others on request
Materials:
stainless steel Mat. No. 1.4571,
Hastelloy® C4, PVDF, titanium

 

  • Calibration
  • Service deployment (on-site inspection / maintenance)
  • Repair
  • Customer consulting by phone
  • Extended warranty (on request if required)

Go back

Product advice

If you have any questions or require a custom solution please call us or write us.
We look forward to hearing from you.

Your contact partner

icon service
Michael Jüch
Sales
icon location

MECON GmbH
Röntgenstraße 105
50169 Kerpen


icon contact

Phone: +49 (0)2237 600 06-0
Fax: +49 (0)2237 600 06-40