MENKAR

Scalable and flexible level indicator for closed and open containers

MENKAR series level indicators are suitable for continuous measurement and monitoring of the level of a liquid in flexibly shaped open or closed containers. The liquid level in the container to be monitored is transferred by a float in a 1:1 ratio as an analogue value. The measurement is independent of the operating pressure. The devices are characterised by the robust structure, fault-free use and good legibility, even from further away.

Various magnetically operated contact units for control and regulation processes (acoustic and optical signals, motor and valve controllers or similar) are available as accessories. Besides a certain minimum distance, the contacts can be fitted in any order and number.

Accessories

Article number
Product
Price*

No products have been found.

*incl. VAT.

Applications:

MENKAR series level indicators are suitable for continuous measurement and monitoring of the level of a liquid in flexibly shaped open or closed containers. The robust design facilitates use under tough conditions. Various types of process connections and floats fulfil the diverse conditions of the industry.

The MENKAR K level indicator is used in the following industries:

  • Plant and mechanical engineering
  • Chemicals
  • Food
  • Metal extraction, production and processing
  • Oil and gas
  • Water and wastewater

Advantages of the level indicator:

  • Continuous level monitoring
  • Universal applications for almost all types of liquids
  • Simple installation thanks to sandwich structure
  • Can be used for pressures up to 320 bar (optional)
  • Can be used for temperatures up to +398 °C (optional)
  • Robust design
  • Powerful magnetic coupling system
  • Good legibility
  • No hydraulic connection between the display unit and the medium
  • Functions without auxiliary energy
  • Also available with a magnetic flap display, percentage scale and 4 – 20 mA output
  • Any number of contacts and contact layout: only restricted by contact housing dimensions
  • High measurement / displayed range. From 200 mm to 5.000 mm. Also in separate version
  • Easy to install
  • Also available with a magnetic flap display, percentage scale and 4 – 20 mA output
  • Low maintenance

Measuring tube connections:

  • DIN EN 1092-1: DN 15 ... DN 50
  • ANSI B 16.5: 1/2" ... 2"
Measuring ranges Liquids: 300 mm ... 5.000 mm
Resolution ± 5 mm
with magnetic flapper display: ± 10 mm
Pressure limits max. 320 bar
Temperature limits -20 °C ... +398 °C
Process connections DIN 2501: DN 15 ... DN 50
ANSI B 16.5: 1/2" ... 2"
Options magnetic flapper display
contact(s)
electrical transmitter

 


Arrange a consultation appointment

If you still have questions or need a special solution, please call or write us!